Product features
  • Battery operates more than 8 hours under full load
  • Choice of Power Modules for 120 or 240 VAC operation
  • ±2 volt analog output
  • Conforms to CE Standards
  • Dual input - for single or differential modes
  • Normal/Reverse transducer setting
  • Selectable ranges in either Inch or Metric units
  • Calibration adjustments for each input
  • Convenient, front-mounted controls
  • Tilt base provides stable support and easy adjustment for best viewing angle
  • The essential performer for today’s slim budgets
  • Technical data

Order no.Product typeRange of analog display µmRange of analog display inchesGraduation mmGraduation value inchCompatibilityMeasuring combinationResponse time analog displayResponse time analog outputAnalogue output
2121404
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121405
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121421
830F
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121422
830F
± .01'' / ± .002" / ± .0004"
500 µ" / 100 µ" / 20 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121424
830F
± 200 / ± 50 / ± 10
± .004" / ± .001'' / ± .0001''
10 / 2,5 / 0,5
200 µ" / 50 µ" / 5 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121425
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121431
830F
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121432
830F
± .01'' / ± .002" / ± .0004"
500 µ" / 100 µ" / 20 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121434
830F
± 200 / ± 50 / ± 10
± .004" / ± .001'' / ± .0001''
10 / 2,5 / 0,5
200 µ" / 50 µ" / 5 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121441
830F
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121442
830F
± .01'' / ± .002" / ± .0004"
500 µ" / 100 µ" / 20 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc
2121444
830F
± 200 / ± 50 / ± 10
± .004" / ± .001'' / ± .0001''
10 / 2,5 / 0,5
200 µ" / 50 µ" / 5 µ"
Federal
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
± 2 Vdc

Metrology
Millimar 830M Compact Amplifier
EN
  • Battery operates more than 8 hours under full load
  • Choice of Power Modules for 120 or 240 VAC operation
  • ±2 volt analog output
  • Conforms to CE Standards
  • Dual input - for single or differential modes
  • Normal/Reverse transducer setting
  • Selectable ranges in either Inch or Metric units
  • Calibration adjustments for each input
  • Convenient, front-mounted controls
  • Tilt base provides stable support and easy adjustment for best viewing angle
  • The essential performer for today’s slim budgets
  • Technical data

Order no.Product typeRange of analog display µmRange of analog display inchesGraduation mmGraduation value inchProbe inputsCompatibilityMeasuring combinationResponse time analog displayResponse time analog outputData interfaceAnalogue outputEnergy supply
2121404
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
2
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
none
± 2 Vdc
110 V / 60 Hz
2121405
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
2
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
none
± 2 Vdc
230 V / 50 Hz / Mains adapter
2121425
830M
± 100 / ± 20 / ± 10
± .004" / ± .001'' / ± .0002"
5 / 1 / 0,5
200 µ" / 50 µ" / 10 µ"
2
Mahr
+A, -A, +B, -B, A+B, +A-B, -A+B, -A-B
0.5 s
0.015 s
none
± 2 Vdc
240 V /50 Hz (UK)